Wind Ranger Technical Specifications

Microprocessor controlled EEPROM embedded for set point data storage LCD character display 2 by 20 line with LED backlighting Relay outputs switch up to 10 amps Sealed keypad to meet NEMA 4/12 conditions Polycarbonate/fiberglass reinforced enclosure to meet NEMA 4/12 conditions.

General Specifications

Display

  • Format – 2×20 LCD Character Display
  • Backlight Color – Black/White LED
  • Pixel Color – Dark Blue
  • Character Resolution – 5×8 Dot Matrix
  • Display Size – 3.2″x0.7″

Enclosure

  • Material – Fiberglass Reinforced Polyester
  • Ratings – Nema Types 1, 3, 4X, 6P, 12

Keypad Overlay

  • Material – Autoflex EBG Polyester
  • Coatings – Solvent Resistant Velvet Textured
  • Hardcoat, Except LCD Display Window
  • LCD Window – Clear Gloss Coating
  • Switches – Pillow Embossed with Tactile Feedback
  • Adhesive – 3M 467MP

Power Requirements

  • Input Voltage – 120/240VAC, 12VAC/DC
  • Max Power Consumption – 6 VA

Relay Outputs

Load – Resistive

  • Rated Load Capacity – 10A at 120V/AC, 8A at 30V/DC
  • Max. Load Capacity – 10A at 250V/AC, 8A at 125V/DC
  • Min. Load Capacity – 100mA at 5V/DC

Life Expectancy at Rated Load –

  • 10,000,000 Mechanical Minimum
  • 100,000 Electrical Minimum

Wind Sensor Input

AC Signal Producing Approximately:

  • 0.17V/AC rms at 5 MPH
  • 0.35V/AC rms at 10 MPH
  • 0.88V/AC rms at 25 MPH
  • 1.77V/AC rms at 50 MPH
  • 3.37V/AC rms at 100 MPH

Wind Controller

Terminal Block Layout

All Wind Rangers Controller Terminal Blocks are clearly marked as shown. The text noted below each terminal block, including stage 1, 2 and 3 are silk screened on the P.C. Board.
The drawing reflects a typical single stage pump cut-off.
When Stage1 Energizes it cuts-off pump or other devices
Twisted pair wiring at a maximum of 500′ when connecting anemometer.